Equipment Bulletins
In order to keep your equipment in top running shape, we will post any bulletins or notifications here for your review. If you have a question that isn't answered here, don't hesitate to contact us.
2006
- Selected 2006 SXPs Equipped With 14 Foot Heads - July 24, 2006
To ensure proper retention of a bearing, a special hold down bracket has been developed
- EZ Retainer Installation Instructions - All 2006 SXPs Equipped With 14 Foot Heads - July 24, 2006
To improve the accuracy of the vibrator speed control, the original controls have been upgraded
- Flow Control Change Instructions - All SXPs Built Before February 2006 - June 29, 2006
Informational bulletin including information about a engine pre-filter
- Letter Sent To Customers
- Filter Cleaning Procedure - SXP 14 Foot Heads Built Before March 21, 2006 - April 3, 2006
Verify proper location of mounting hole on Auger Support Beam
- Measurement Instructions - PowerRake With Serial Numbers 40001 to 40082 - March 24, 2006
Some customers have experienced premature failure of the hitch. Replacement hitches are being sent to customers as a preventative measure
- Letter Sent To Customers
- Replacement Procedure
2005
- CopperHead XD Operational Tips - November 30, 2005
To clarify the proper settings for the XD 2.0 vibrator adjustment feature, an updated operation section is sent to all owners
- XD Operational Tips Bulletin - CopperHead XDs With Serial Numbers 20426-20468 - November 16, 2005
Some accumulators used in the vibrator "soft start" feature were not charged properly. Replacement parts have been shipped to all customers. - SXP Laser Screeds 30000-30114 - November 15, 2005
More detailed instructions have been added to the maintenance section of customers manuals. This manual section is being sent to all screeds
- SXP Maintenance Manual - CopperHead XDs With Serial Numbers 20426-20466 and 20468 - November 7, 2005
An incorrect rubber isolator may have been installed on these units. Replacement parts have been shipped to all customers to ensure optimum performance.
- Read Procedure On Replacement - PowerRakes With Serial Numbers 40001-40029, 40032, and 40033 - October 3, 2005
These machines may have an improperly set speed on the steering valve will may reduce machine pulling power.
- Read Procedure On Adjustment - Possible Auger Shipment Mistakes - August 17, 2005
Several shipping mistakes for S240/SXP-12.5 augers have been found in 2005. All U.S. customers who have purchased an auger from Somero are asked to inspect their inventory for accuracy. - SXP Laser Screeds Equipped With Catalytic Mufflers In Serial Number Range 30000-30092 - July 26, 2005
The fan shroud needs to be replaced to prevent damage to the fan assembly
- Read Letter Sent To Customers - SXP Laser Screeds With Serial Numbers 30054 to 30094 - July 24, 2005
An improvement to the 2005 SXP Boom Cord has been made. Replacement cords were sent to all customers.
- Read Letter Sent To Customers - STS-132 Topping Spreaders - July 13, 2005
An improvement to the maintenance section of the manual is being sent to all customers
- Read Letter Sent To Customers - SXP Laser Screeds With Serial Numbers 30000 to 30092 - July 13, 2005
A minor error found on a machine decal. Replacement decals were sent to customers
- Read Letter Sent To Customers
2004
- SXP Laser Screeds With Serial Numbers 30000 to 30034 - September 8, 2004
To ensure adequate strength, auger support beam reinforcement is required
- Read Letter Sent To Customers - S-160 and S-240 With System 1 Self-Level Controls - January 19, 2004
Machines originally built before 1996 may be equipped with a self level control system that is no longer supported.
- Read Letter Sent To Customers
2003
- CopperHead S-9210 Machines With Serial Numbers 10299 to 10345 - December 11, 2003
Some machines may need a cartridge replaced to ensure proper long term performance. Locate date code on manifold and replacement cartridge will be sent out.
- Read Letter Sent To Customers - 3-D Profiler Owners With Geodimeter 4000 Units - October 24, 2003
To ensure proper operation, the engineering units on the Geodimeter 4000 need to be properly set.
- Read Letter Sent To Customers
- Owners Manual Pages - 3-D Profiler Owners In United States - October 17, 2003
The FCC is requiring licensing for all radios used as part of the 3D system.
- Read Letter Sent To Customers
- Read FCC Policy